Introduction to radiometry
Radiometry is the measurement of radiation in the electromagnetic spectrum. This includes ultraviolet (UV), visible and infrared (IR) light.
Electromagnetic radiation is characterized by its frequency of oscillation. The frequency determines the "color" of the radiation (see Figure 1). The speed of light is a constant, and frequency is related to wavelength by the relationship:
C = lg
C = speed of light
l = wavelength
g = frequency
The preferred units of measure for wavelength are nanometers (nm) and micrometers (µm, or "microns").
The visible region of the electromagnetic spectrum can be divided into the basic colors of the rainbow: red, orange, yellow, green, blue, indigo and violet. Red light has the longest wavelength in the visible region (770 nm). Violet has the shortest (380nm).
Ultraviolet light is shorter in wavelength than visible light. It extends from 10 nm to 380 nm. And like the colors of the visible region, UV can be subdivided into smaller regions. The UVA region ranges from 380 nm down to 340 nm and is the least harmful of UV radiation. The vacuum-ultraviolet (VUV) and UVC regions are shorter and are important to the study of cancer.
Infrared light extends from 770 nm to 100 microns. Its regions are known as near-IR, mid-IR and far-IR.
Measurements of optical radiation require specific methods to obtain accurate measurements. UDT supplies calibrated detector/filter combinations that cover from 200-1800 nm (0.2 to 1.8 mm). To obtain accurate measurements, one must understand the light source (i.e. laser, lamp, LED); the optical medium (i.e. air, water, optics); and the particular response characteristics of the detector.
Radiometers
Model S350 Optometer
Model S370 Single-Channel Optometer
Model S380 Dual-Channel Optometer
Model S471 Portable Optometer (New Handheld
Optometer)
Radiometric Sensor Heads
Model 221 Silicon Sensor Head
Model 222UV Blue Enhanced Sensor Head
Model 228 HeNe Sensor Head
Model 247 Flat Response (450-950) Sensor Head
Model 260 Silicon Sensor Head
Model 261 Germanium Sensor Head
Model 262 Flat Response (450-950) Sensor Head
Model 264 Laser Sensor Head
Model 268R Flat Response/Low-Profile Sensor Head
Model 268LP Laser Low Profile Sensor Head
Model 268UVA UVA Optimized/Low Profile Sensor Head
Model 268UVC UVC Optimized/Low Profile Sensor Head
Model 268BLUE UV Blue Optimized/ Low Profile Sensor Head
Model S2575 Sensor/Minisphere Combination
Model S2575R Sensor/Minisphere Combination w/Flat Response (450-950)
Model S2575GE Sensor/Minisphere Combination w/Germanium
Amplifiers
TRAMP Amplifier
Laser Power Attenuators
Model 2575 Integrating Sphere
Model 2500 Integrating Sphere
Model 2525 Integrating Sphere
Model 2550 Attenuators
Housing, Stands And Adapters
Model 101-1 Universal Sensor Housing
Model 102 Filter Holder
Model 103 Standard Lab Stand
Model 104 Filter Holder And Coupler
Model 104-Mini Filter Holder And Coupler
Model 108 Male Coupler
Model 108-Mini Male Coupler
Model 109 Heavy-Duty Lab Stand
Model 1718 Set-up Adapter